That ground rod, for lack of bonding to the rest of the system, was irrelevant. Pipe Grounding Clamp. Contact resistance between the electrode and the soil adjacent to it. This can result in a continuity test being performed rather than a ground resistance test. Skill with the tester is more important than which to use.
The measurement of ground resistance for an earth electrode system is very important.

There are two (2) methods for testing an electrical grounding system. The 3-point or fall-of-potential method is used to measure the resistance-to-ground of existing grounding systems.
Grounding system testing is performed in and around high voltage (HV) Grounding systems allow a proper connection from your system's neutral to global. Why the first category? Your electrical system needs a low impedance path to ground for protecting people and equipment.
Why the second?.
In a year or so, earth electrode systems that formerly were effective may end up in dry earth of high resistance. Exposed external earthing or grounding conductor connection joints are to be protected from corrosion with grease caps or Denso tape bituminous tape or approved equal.
8 practical applications of testing ground system using clampon tester EEP
The clamp-on can be placed around the cable connecting the ground bar to the electrode to perform a test. The 10 Most Popular Photo Galleries of Large Ground Clamp.
The backfill in the vicinity of the conductor shall be free of stones and the whole backfill shall be well consolidated.
You may have other concerns beyong the NEC. It is not enough to check the earth resistance only at the time of installation.
Learn What is Earth Ground Test, Why and How is it Done.
Also to be included are portable electrically operated devices. Many lightning protection systems on factory buildings, especially in European countries, use lightning receptors mounted at regular intervals on the roof.

In many locations, the water table is gradually falling.
Measurement of earth ground resistance for an earth electrode system should be low resistance path for electric current to protect personnel and equipment. There are two types of ground testing that should be performed at your facility.

Grounding fault systems primarily protect equipment, while ground fault circuit.
The induced frequency test can test grounding systems that are in use and does not require the interruption of service to take measurements. Search Our Website.
Grounding system testing OMICRON
The 10 Most Popular Photo Galleries of Additional earth rods connecting with the earth ring are to be provided, as necessary, to bring down earth electrode resistance to an acceptable value. This is because the utility or telecom neutral connection remains on the grounding system.
![]() Testing grounding systems protection |
Over time, connections or bonds can loosen.
But there are three important limitations: The waterpipe system must be extensive enough to have a negligible resistance. Video: Testing grounding systems protection Resistance to Ground Testing Lightning Protection Systems - Northeast Lightning Protection CT Download our free article which covers 7 common electrical grounding design mistakes. The clamp-on can be placed around the cable connecting the ground bar to the electrode to perform a test. The veracity of the Induced Frequency Test has been questioned due to testing errors, however when properly applied to a small to medium sized, self-standing grounding system, this test is rapid and reasonably accurate. The neutral earthing ground rod pit is to be also clearly identified. There are two 2 methods for testing an electrical grounding system. |
The correct methods and equipment must be used to produce the right data for your grounding system.
Ground Connection of building Ground Bus.
If you replace bonding jumpers, add equipment, or modify the grounding system, it's good to repeat this test. Bonding is what you do to connect your system components to the grounding system.
Such changes create different needs in the earth electrode.